Threaded Flanged Indoor Hydrant DN65
video

Threaded Flanged Indoor Hydrant DN65

Indoor fire hydrants with DN65 inlet and outlet, flange or thread connection. Used for indoor fire protection in power substations and industrial buildings.
Customization is accepted and OEM is welcome. FOB price runs from US $5-70 per piece, MOQ 30 pieces.
Send Inquiry
Product Introduction

Threaded Flanged Indoor Hydrant DN65

Inside the power substation equipment room

This indoor hydrant serves the interior of a power substation, mounted on the riser take-off in a cabinet along an equipment room wall, control room approach or corridor inside the electrical building. The indoor class of unit stays dry between drills, paired with a hose roll and nozzle in the same cabinet, and it feeds vertical riser water rather than an outdoor standing main. Substation rounds check each cabinet door on the inspection lap, and the hydrant inside gets the same inspection cycle as the hose roll beside it. Electrical layouts separate transformer bays, switchgear rooms, battery areas and control rooms, and each branch keeps its own hydrant at the take-off shown on the fire drawing. The source record leaves listed application open, so the service scope follows the substation fire system specification reviewed at tender. The unit belongs to the indoor hydrant family rather than the buried pillar class, and it connects to a riser branch rather than a yard main.

The hydrant sits in the cabinet. The hose roll parks beside it.

DN65 bore with plain listed model field

The specification lists a DN65 bore, matching a sixty-five-millimetre branch off the building riser, and bore size decides flow through the branch, so it should align with the hose or feed line the cabinet serves on the room layout. The model reference field carries no assigned value on the listing, and no variant code is printed beside the bore size; the body is selected by bore, end form and the cabinet drawing rather than a listed model code. Material carries no assigned value, and pressure class and certification record are marked open; line rating and any required approval are confirmed against the substation fire system specification reviewed at tender rather than assumed from the body shape. Where the project schedule names a variant at each take-off, maintenance replaces like for like so the branch hydraulic role stays unchanged after a swap. The plain model field means buyers match the body to the riser branch shown on the drawing before the order is cut, rather than substituting a larger or smaller body on site.

The bore runs DN65. The model field is left open on the listing.

Threaded and flanged connection options

The joint type lists flange connection and thread connection as end options. Threaded ends screw onto a male connection where standard wrenches break the joint open, suited to smaller branches where a flange would crowd the cabinet recess. Flanged ends bolt through a companion flange on the riser take-off with gasket and even torque, a rigid joint suited to larger branches where the crew wants a repeatable seal that opens and reseals during maintenance. The end form follows how the electrical riser was built, and the room schedule states flange or thread per cabinet; a mixed match needs an adapter inside the wall recess, which crowds the box and adds another seal face to inspect. Before the joint closes, the sealing face gets wiped clean, because grit left in the bore or on the thread is the usual reason a fresh connection weeps after the first pressure test.

Thread screws onto the male take-off. Flange bolts to the companion face.

Threaded flanged indoor hydrant DN65 in a power substation room
Indoor hydrant cabinet placed inside an electrical substation building.

Indoor placement in electrical buildings

Electrical building layouts place cabinets along equipment room walls, corridor edges and control room approaches, where a short hose reach covers the nearest switchgear row, doorway or panel area. Each hydrant acts as the isolation point for the branch it feeds and the connection point for a response, so one section can be closed for work without draining the whole riser. Indoor dust, occasional moisture from ventilation and cleaning spillage settle on exposed hydrant faces between rounds, and the inspection cycle wipes the stem, checks the seat and looks for weep around the connection before the roll returns to the cabinet. Spare bodies sit in the building store held by bore, end type and cabinet position, so a failed hydrant swaps without a special procurement trip. On paper the bore is one number; in the room it decides how much water reaches the hose at the cabinet. Maintenance cycles the body on each visit, wipes the stem and seat, and confirms the connection stays dry between drills.

One branch closes at a time. The rest of the riser keeps its pressure.

Indoor supply and order notes

Industrial projects supply hydrants in batches by room or building section, and custom models are accepted when a riser layout calls for a non-standard outlet arrangement. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity. Before packing, the end connection gets a protector and the valve rests closed; at receiving, match the body to the cabinet drawing and confirm the end form mates with the riser take-off. The source record leaves material, pressure class and certification open, so those fields follow the substation fire system specification reviewed at tender rather than a fixed rating printed on the listing.

ListingReading
Listed unit classFire Hydrant
Model reference-
Bore scheduleDN65
End connectionFlange Connection, Thread Connection
Working pressure band-
Certification record-
Body composition-
Listed application-
Product categoryFire Hydrant

Hot Tags: Threaded Flanged Indoor Hydrant DN65, China Threaded Flanged Indoor Hydrant DN65 manufacturers, fire hydrant, fire hydrant assembly parts, fire hydrant cap, fire hydrant hose connection, fire hydrant key, fire hydrant pipe system

Send Inquiry

whatsapp

Phone

E-mail