1.6MPa DN65 Hydrant Valve
video

1.6MPa DN65 Hydrant Valve

Fire fighting hydrant valve in Sn65, SNW65, SNZ65 and SNS65, DN65, rated 1.6 MPa, flange or thread ends. Commonly used for indoor fire pump connections in building fire water systems.
Custom models are accepted, FOB pricing runs US $5-50 per piece, min. order 30 pieces.
Send Inquiry
Product Introduction

1.6MPa DN65 Hydrant Valve

Valves on the hospital fire pump connection

This hydrant valve sits on the indoor fire pump connection of a hospital fire water system, acting as the branch shut-off where pump discharge meets the riser network feeding ward corridors, stairwells and treatment wings. The valve body serves the hospital indoor fire protection role listed on the source record, tied to building water supply fire service rather than an outdoor street pedestal. On a hospital layout these valves repeat at pump headers and riser take-offs, each isolated so maintenance can work one branch without draining the whole system. The body stays dry between drills and cycles during routine pump and riser checks.

Hospital maintenance works branch by branch. A closed valve keeps the rest of the riser live during repair.

1.6MPa rating on the DN65 body

The specification lists a DN65 bore, and the pressure class reads 1.6MPa, a working pressure band that matches the rated hospital fire water header shown on the system drawing. Bore size decides flow through the branch, while the pressure rating decides whether the body holds the line under pump discharge conditions; both should align with the riser schedule reviewed at tender. Material carries no assigned value on the listing, and the certification record is marked open, so any required approval is confirmed against the hospital fire system specification before supply. Buyers do not substitute a lower-rated body onto a 1.6MPa branch on site.

DN65 sizes the flow. 1.6MPa sizes the rating. The drawing lists both.

Flange and thread end alternatives

The joint type lists flange connection and thread connection as alternatives, the two end forms used to tie the valve onto the pump header or riser take-off. Flanged ends bolt through a companion flange with gasket and even torque, suited to rigid header branches; threaded ends screw onto a male connection where crews break the joint with standard tools. The end form follows how the hospital header was built, and the project schedule states flange or thread for each connection. A mixed end match needs an adapter, which adds length and another seal face inside the plant room or cabinet.

1.6MPa DN65 hydrant valve at a hospital pump connection
Indoor hydrant valve serving a hospital fire water system.

Sn65 to SNS65 variant lineup

Model references read Sn65, SNW65, SNZ65 and SNS65, the same four-variant indoor hydrant family used across building risers. The base Sn65 is the standard body; SNW65 adds regulating function, SNZ65 uses a rotary arrangement, and SNS65 carries a double-outlet configuration. The riser schedule names the variant at each take-off, and maintenance replaces like for like so the branch hydraulic role stays unchanged.

How hospital risers split by ward wing

Spare valves are stored alongside pump spares and riser fittings, held by DN65 bore, pressure rating and end type, so a failed body swaps without a special procurement trip. Routine visits cycle the valve, inspect the seat and stem, and check for weep at the connection; a stiff stem or leaking seal sends the body to the repair bench. Custom variants are accepted when a hospital riser layout calls for a non-standard outlet arrangement.

Where spare valves sit in the hospital store

The hospital fire water system splits the main into risers for each ward wing, treatment block and public area, and the hydrant valves sit on those riser take-offs and pump header branches as the isolation and connection points. A hospital layout separates inpatient wards from diagnostic rooms, corridors and refuge floors, and each branch can be closed at its valve while maintenance works on one section without draining the whole system. The DN65 body matches the branch bore on the schedule, and the 1.6MPa rating matches the header pressure shown on the hospital fire system drawing, so the body holds pump discharge conditions without substitution. During pump and riser checks the valve cycles open and closed, seat and stem get wiped, and any weep at the connection marks the body for the repair bench. Spare valves sit beside pump spares in the hospital store, held by bore, rating and end type, so a failed body swaps without a special trip to procurement.

One valve per branch. Close that branch and the rest of the riser keeps its water.

Hospital service areas carry cleaning moisture, corridor dust and occasional disinfectant spillage around the plant room and cabinet locations, and that residue settles on exposed valve faces between maintenance rounds. The four model variants on the record serve different branch roles: standard Sn65, regulating SNW65, rotary SNZ65 and double-outlet SNS65, and the riser schedule names the variant at each take-off. Maintenance replaces like for like so the branch hydraulic role does not change after a swap. Material and certification record carry no assigned values on the listing, and the required approval is confirmed against the hospital fire specification at tender.

The hospital system splits the main into risers for each ward wing, treatment block and public area, and the hydrant valves sit on those take-offs and pump header branches as the isolation and connection points. A hospital layout separates inpatient wards from diagnostic rooms, corridors and refuge floors, and each branch can be closed at its valve while maintenance works on one section without draining the whole system. The DN65 body matches the branch bore on the schedule, and the 1.6MPa rating matches the header pressure shown on the hospital fire system drawing, so the body holds pump discharge conditions without substitution. During pump and riser checks the valve cycles open and closed, seat and stem get wiped, and any weep at the connection marks the body for the repair bench. Spare valves sit beside pump spares in the hospital store, held by bore, rating and end type, so a failed body swaps without a special trip to procurement. The four variants serve standard, regulating, rotary and double-outlet roles, and the riser schedule names the variant at each take-off before supply. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity.

ReferenceMeasure
Working pressure band1.6MPa
End connectionFlange Connection, Thread Connection
Body composition-
Listed unit classHydrant Valve
Bore and outlet scheduleDN65
Certification record-
Model referenceSn65/Snw65/Snz65/Sns65
Product categoryHydrant Valve
Listed applicationHospital Water Supply Fire Protection

Hot Tags: 1.6MPa DN65 Hydrant Valve, China 1.6MPa DN65 Hydrant Valve manufacturers, Corrosion resistant Outdoor Fire Hydrant, fire hydrant cap, fire hydrant coupling, fire hydrant hose connection, fire hydrant key, fire hydrant repair parts

Send Inquiry

whatsapp

Phone

E-mail

Inquiry