Pressure Regulating DN65 Hydrant Valve
video

Pressure Regulating DN65 Hydrant Valve

Pressure-regulating fire fighting hydrant valve in SQS100 and SQS150, DN65, rated 1.6 MPa, flange or thread ends. Commonly used for office and commercial building fire risers.
Custom models are accepted, FOB pricing runs US $5-50 per piece, min. order 30 pieces.
Send Inquiry
Product Introduction

Pressure Regulating DN65 Hydrant Valve

On the office building fire riser

This hydrant valve sits on the fire riser of an office building, where the branch off the vertical main feeds an indoor cabinet or a landing connection on each floor. The valve body acts as the isolation point for that branch and the connection point for a hose run, so one floor section can be closed for work without draining the whole riser. Listed application on the source record is office building fire protection, covering the valve connections of commercial premises with stairwells, open plan floors and shared service cores. The SQS series covers two listed model references, SQS100 and SQS150, both carried on the DN65 listing. Riser rounds check each valve on the floor schedule, wipe the stem and seat, and look for weep around the end joint before the cabinet door closes. Between drills the body stays dry, paired with the hose and nozzle parked in the same cabinet, and the valve rests closed until a response or a drill opens it. The office layout separates meeting rooms, desk floors, lobby areas and service shafts, and each branch keeps its own valve at the take-off shown on the fire drawing.

One branch closes at a time. The rest of the riser keeps its water.

SQS model variants and the DN65 bore

The model references read SQS100 and SQS150, the two variants of the SQS hydrant valve family listed on the record. The specification lists a DN65 bore, matching a sixty-five-millimetre branch off the building riser, and bore size decides flow through the valve, so it should align with the hose or feed line the cabinet serves on the floor layout. The regulating function adjusts pressure along the branch, keeping the delivery within the range the indoor hose run expects, and the variant chosen at each take-off follows the riser schedule on the project drawing. Material carries no assigned value on the listing, and the certification record is marked open; line rating and any required approval are confirmed against the office fire system specification reviewed at tender rather than assumed from the valve shape. The cabinet schedule names the variant at each take-off, and maintenance replaces like for like so the branch hydraulic role stays unchanged after a swap.

The bore runs DN65. The two SQS variants cover the listed riser branches.

Flange and thread end options

The joint type lists flange connection and thread connection as end options. Flanged ends bolt through a companion flange on the riser take-off with gasket and even torque, a rigid joint suited to larger branches where the crew wants a repeatable seal that opens and reseals during maintenance. Threaded ends screw onto a male connection where standard wrenches break the joint open, suited to smaller branches where a flange would crowd the cabinet recess. The end form follows how the office riser was built, and the floor schedule states flange or thread per valve; a mixed match needs an adapter inside the wall, which adds another seal face to inspect and another part to carry in the store. Before the joint closes, the sealing face gets wiped clean, because grit left in the bore or on the thread is the usual reason a fresh connection weeps after the first pressure test.

Flange bolts to the companion face. Thread screws onto the male take-off.

Pressure regulating DN65 hydrant valve on an office building riser
SQS hydrant valve staged beside a commercial building fire riser.

1.6MPa rating and what it covers

The pressure class lists 1.6MPa, the working rating carried on the source record for this valve series, and it should be matched to the indoor water service the riser branch feeds. The rating covers the body and seat under the listed working condition, while surge, temperature and fluid service follow the office fire system specification reviewed at tender. The certification record carries no assigned value on the listing, so any project-specific approval is confirmed against the tendered documentation rather than added to the valve description. The product category on the source record is Hydrant Valve, reflecting the regulating valve body that mounts on the riser branch. Buyers match the valve bore, pressure rating and end form to the floor drawing before the order is cut, rather than substituting a body that does not match the cabinet recess.

The working rating reads 1.6MPa. The body and seat carry the listed service.

Rounds check the regulating stem and seat on each visit, wiping residue off the body before confirming the branch connection stays dry. Office riser schedules name the SQS variant at each take-off, and maintenance replaces like for like after any swap.

Valve supply notes

Commercial projects supply valves in batches by floor or building block, and custom models are accepted when a riser layout calls for a non-standard outlet arrangement. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity. Before packing, the end connection gets a protector and the valve rests closed; at receiving, match the body to the cabinet drawing and confirm the end form mates with the riser take-off. The source record leaves material and certification open, so those fields follow the office fire system specification reviewed at tender rather than a fixed rating printed on the listing.

TagSpecimen
Listed unit classHydrant Valve
Model referenceSQS100, SQS150
Bore scheduleDN65
End connectionFlange Connection, Thread Connection
Working pressure band1.6MPa
Certification record-
Body composition-
Listed applicationOffice Building Fire Protection
Product categoryHydrant Valve

Hot Tags: Pressure Regulating DN65 Hydrant Valve, China Pressure Regulating DN65 Hydrant Valve manufacturers, fire hydrant assembly parts, fire hydrant distribution system, fire hydrant key, fire hydrant outlet, fire hydrant pipe system, Outdoor Fire Hydrant

Send Inquiry

whatsapp

Phone

E-mail

Inquiry