Automatic Drainage Hydrant Valve
Custom models are accepted, FOB pricing runs US $5-70 per piece, min. order 30 pieces.
Automatic Drainage Hydrant Valve
Self-draining valves on critical-site mains
This hydrant valve carries an automatic drainage feature, installed on critical-site and industrial fire mains where standing water inside the body after use would otherwise freeze, stagnate or leave residue behind. Listed application on the source record is nuclear power site fire protection, the high-importance class of hydrant valve found around controlled industrial premises and critical plant areas. The valve acts as the branch shut-off and connection point on the fire water header, isolated so maintenance can work one branch without draining the whole system. The drainage function operates when the hydrant closes, releasing residual water from the body so the next response starts from a dry barrel.
On a critical site, leftover water in the body is a problem. The drain clears it after the valve shuts.
Automatic drainage after the hydrant closes
The automatic drainage arrangement vents residual water from the body once the internal pressure drops after shut-off, avoiding a trapped barrel that sits wet between drills. This suits cold or critical environments where ice blockage, stagnant water or internal residue would otherwise compromise the next use. Drainage should be checked on routine visits: the valve closes, the body vents, and no water pools around the connection afterward. Material carries no assigned value on the listing, and pressure class and certification record are marked open, so line rating and required approval follow the critical-site fire system specification reviewed at tender.
Close the valve and the drain does the rest. The body stays dry until the next opening.
DN65 take-off ends at the critical-site main
The specification lists a DN65 bore, and the joint type lists flange connection and thread connection as end options. Flanged ends bolt to a companion flange on the header take-off; threaded ends screw onto a male connection where standard tools open the joint. The end form follows how the critical-site main was built, and the project schedule states flange or thread at each connection. An end mismatch forces an adapter into the branch, adding length and another seal face to inspect.

SN65 to SNS65 variant set
Model references read SN65, SNW65, SNZ65 and SNS65, the four-variant hydrant family used on critical-site headers. The base SN65 is the standard body; SNW65 carries regulating function, SNZ65 uses a rotary arrangement, and SNS65 carries a double-outlet configuration. The site schedule names the variant at each take-off, and maintenance replaces like for like so the branch hydraulic role stays unchanged. Variant selection follows the drawing callout rather than stock substitution, since a regulating, rotary or double-outlet body serves a different role on the line.
How critical-site headers isolate branches
Critical-site projects supply valves in batches by header section or controlled area, and custom variants are accepted when a main layout calls for a non-standard outlet arrangement. Before dispatch, confirm end form and variant against the site drawing. At receiving, mate the body to a sample companion flange or male thread, check the seat face, and verify the drainage path clears after a trial close before the valve enters service.
What rounds verify on the drain path
The critical-site fire header runs through the industrial area and branches to each controlled zone, with the hydrant valve on those branches as the isolation point that lets maintenance close one section without draining the rest of the network. Nuclear and critical premises separate reactor auxiliaries, storage areas, pump houses and outer yard zones, and each branch can be worked on while the other connections stay pressurized. The DN65 body matches the branch bore on the site schedule, and the automatic drainage feature vents residual water after shut-off so the body does not hold a trapped barrel between responses. During routine checks the valve cycles open and closed, the drain path is confirmed clear after a trial close, and any weep at the connection marks the body for bench repair. Spare valves sit in the site store held by bore, variant and end type, so a failed body swaps without a special procurement trip.
One valve per branch. Close it, the drain clears the body, and the rest of the header stays live.
Critical-site interiors carry controlled-area dust, ventilation moisture and cleaning residue, and that load settles on exposed valve surfaces between maintenance rounds. The four variants on the record cover standard SN65, regulating SNW65, rotary SNZ65 and double-outlet SNS65 roles, and the site schedule names the variant at each header take-off; maintenance replaces like for like so the branch role stays unchanged after a swap. Pressure class and certification record carry no assigned values on the listing, and the rating follows the critical-site fire system specification reviewed at tender. Flanged and threaded ends both appear on the record, and the end form is confirmed against how the main was built before supply. Custom variants are accepted when a header layout calls for a non-standard outlet arrangement.
The critical-site header runs through the industrial area and branches to each controlled zone, with the hydrant valve on those branches as the isolation point that lets maintenance close one section without draining the rest of the network. Nuclear and critical premises separate reactor auxiliaries, storage areas, pump houses and outer yard zones, and each branch can be worked on while the other connections stay pressurized. The DN65 body matches the branch bore on the site schedule, and the automatic drainage feature vents residual water after shut-off so the body does not hold a trapped barrel between responses. During routine checks the valve cycles open and closed, the drain path is confirmed clear after a trial close, and any weep at the connection marks the body for bench repair. Spare valves sit in the site store held by bore, variant and end type, so a failed body swaps without a special procurement trip. The four variants cover standard, regulating, rotary and double-outlet roles, and the site schedule names the variant at each header take-off before supply. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity.
| Component | Reading |
|---|---|
| End connection | Flange Connection, Thread Connection |
| Bore and outlet schedule | DN65 |
| Working pressure band | - |
| Listed application | Nuclear Power Site Fire Protection |
| Certification record | - |
| Listed unit class | Hydrant Valve |
| Model reference | SN65, SNW65, SNZ65, SNS65 |
| Body composition | - |
| Product category | Hydrant Valve |
Hot Tags: Automatic Drainage Hydrant Valve, China Automatic Drainage Hydrant Valve manufacturers, above ground fire hydrant, Durable Cast Iron Indoor Fire Hydrant, fire hydrant metal valve body, fire hydrant outlet, Indoor Fire Hydrant, Underground Fire Hydrant