Epoxy Coated Above Ground Fire Hydrant
Custom specifications are accepted and OEM is welcome. FOB pricing runs from US $65 per piece, minimum order 30 pieces.
Epoxy Coated Above Ground Fire Hydrant
An epoxy-coated standpipe for outdoor use
This epoxy-coated above-ground hydrant stands out along a substation, industrial yard or roadside fire loop, rising from the buried riser at the edge of the paving. The epoxy coating covers the exposed exterior body for outdoor weather, and the standpipe stays visible along driveways, apron edges, equipment rows and roadside strips where a buried pit would slow a response. The unit belongs to the above-ground hydrant family rather than the buried cabinet class, and it connects to a buried branch through a base flange. Substation rounds pass the standpipe on every lap, check the cap and outlets, and confirm the body sits plumb in its mounting. The source record leaves listed application open, so the service scope follows the substation fire system specification reviewed at tender. Coating matters where exposed metal would otherwise collect road residue and moisture between inspection rounds.
The standpipe stays outdoors. The coated body handles weather and residue.
Inlet and outlet sizes on the SS range
The model range lists SS100/65 and SS150/80, and the specification records inlet DN100/DN150 with outlet DN65/DN80. The SS100/65 pairs a DN100 inlet with a DN65 outlet, while the SS150/80 pairs a DN150 inlet with a DN80 outlet, so the larger body carries a bigger inlet bore and a wider outlet branch. Inlet size decides how much water the standpipe can feed, and the outlet matches the hose coupling the brigade carries on site. The two variants cover the standard above-ground sizes used around substations, yards and roadside fire points, and the site schedule names the variant at each standpipe position. Material carries no assigned value on the listing beyond the recorded epoxy coating, and pressure class and certification record are marked open; line rating and any required approval are confirmed against the site fire system specification reviewed at tender rather than assumed from the body shape.
Inlet and outlet sizes are recorded per variant. The outlet matches the brigade coupling.
Flanged outlet and base arrangement
The joint type lists flange connection for the body arrangement. The standpipe bolts through a companion flange on the buried riser with gasket and even torque, a rigid joint that keeps the body upright under outdoor weather and occasional side loads from passing traffic. Flanged assembly lets a crew lift the body for maintenance without cutting the buried branch, and the bolt circle and gasket face follow the riser flange on the project drawing. Where the paving settles around the base, the crew checks that the standpipe remains plumb and that no gap opens under the flange, because a tilted body strains the riser joint over time. The outlet branch takes the brigade hose coupling, and the end form follows how the yard main was laid, stated per standpipe on the project schedule.
The base bolts to the riser flange. The outlet carries the hose coupling.

Placement along substations and roadsides
Substation, yard and roadside layouts keep the fire loop along driveways, apron edges, equipment rows and verge strips, with above-ground hydrants spaced where the drawing calls for a reachable outdoor point. Each standpipe acts as the isolation point for the branch it feeds and the connection point for a response, so a section can be closed for work without draining the whole loop. Outdoor dust, pollen, road salt in winter months and runoff from paving settle on the exposed coated body between rounds, and the inspection cycle wipes the outlets, checks the stem and looks for weep around the base flange before the cover goes back on. Spare bodies in the store are held by inlet size, outlet size and base end type, so a failed standpipe swaps without a special procurement trip. On a roadside apron the standpipe has to be obvious from the approach; buried pits would slow a response that relies on sighting the fire point quickly. The coated exterior keeps the body presentable between rounds, with the coating carrying the outdoor weather before any paint or wrap follows the site's own maintenance practice.
Standpipes space out along the loop. Each one closes its own branch.
Rounds mark the coated outlets and base flange on each lap, brushing off dust and salt before checking the joint for weep. The coating carries the outdoor weather between rounds, and the standpipe stays visible along the roadside strip.
Coating and supply notes
Site projects supply hydrants in batches by yard section, equipment row or roadside strip, and custom specifications are accepted when a riser layout calls for a non-standard outlet arrangement. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity. Before packing, the flange face gets a protector and the valve rests closed; at receiving, match the body to the paving drawing and confirm the base mates with the buried riser. The source record leaves material beyond the recorded coating, pressure class and certification open, so those fields follow the site fire system specification reviewed at tender rather than a fixed rating printed on the listing.
| Coating | Finish |
|---|---|
| Listed unit class | Fire Hydrant |
| Model reference | SS100/65, SS150/80 |
| Bore and ports | Inlet DN100/DN150, Outlet DN65/DN80 |
| End connection | Flange Connection |
| Working pressure band | - |
| Certification record | - |
| Body composition | - |
| Listed application | - |
| Product category | Fire Hydrant |
Hot Tags: Epoxy Coated Above Ground Fire Hydrant, China Epoxy Coated Above Ground Fire Hydrant manufacturers, Corrosion resistant Outdoor Fire Hydrant, fire hydrant assembly parts, fire hydrant coupling, fire hydrant metal valve body, fire hydrant network valve, Underground Fire Hydrant