Inlet Outlet DN65 Underground Hydrant
video

Inlet Outlet DN65 Underground Hydrant

Outdoor underground fire hydrants, types SN65, SNW65, SNZ65 and SNS65, DN65 inlet and outlet, flange or thread connection. Commonly used in office building and commercial site fire protection.
Custom specifications are accepted and OEM is welcome. FOB pricing runs from US $5 per piece, minimum order 30 pieces.
Send Inquiry
Product Introduction

Inlet Outlet DN65 Underground Hydrant

Buried beside the office building approach

This underground hydrant sits below grade along the fire loop of an office building and commercial site, where the buried riser branches off the yard main to feed a fire point tucked between approach paving, access lanes and shared apron edges. The body disappears into the trench between the main and the hydrant pit, leaving only the operating stem and cap above the pavement, so visitors and service vehicles move past without a standpipe blocking the route. The unit belongs to the underground hydrant family rather than the indoor cabinet class, and it connects to a buried branch rather than a vertical building riser. Yard rounds walk the loop at set intervals, check the cap and stem, and note any weep around the buried joint before the next drill. Office building and commercial site layouts separate approach drives, parking rows, entry plazas, service lanes and adjoining premises, and each section keeps its own branch off the main fire loop. The source record leaves listed application open, so the service scope follows the site fire system specification reviewed at tender.

The pit stays low profile. Traffic rolls past without a standpipe.

SN model family and equal DN65 ports

The model references read SN65, SNW65, SNZ65 and SNS65, the four-variant underground hydrant family carried on the listing. The base SN65 is the standard buried body; SNW65 adds a regulating function, SNZ65 uses a rotary arrangement, and SNS65 carries a double-outlet configuration. The specification records inlet DN65 and outlet DN65, matching a sixty-five-millimetre branch on both sides of the body, and bore size decides flow through the branch, so it should align with the hose or feed line the fire point serves on the site layout. Material carries no assigned value on the listing, and pressure class and certification record are marked open; line rating and any required approval are confirmed against the site fire system specification reviewed at tender rather than assumed from the body shape. The pit schedule names the variant at each take-off, and maintenance replaces like for like so the branch hydraulic role stays unchanged after a swap.

Inlet and outlet both run DN65. The four variants cover the listed buried roles.

Flanged and threaded end fittings

The joint type lists flange connection and thread connection as end options. Flanged ends bolt through a companion flange on the buried branch with gasket and even torque, a common choice where the main was built with flanged tees and the crew wants a rigid, repeatable joint that opens and reseals during maintenance. Threaded ends screw onto a male connection where standard wrenches break the joint open, suited to smaller buried branches where a flange would crowd the trench walls. The end form follows how the site main was laid, and the project schedule states flange or thread per fire point; a mixed match needs an adapter in the recess, which adds another seal face to inspect and another part to carry in the store. Before the joint closes, the sealing face gets wiped clean, because grit left in the bore or on the thread is the usual reason a fresh connection weeps after the first pressure test.

Flange bolts up to a companion face. Thread screws onto the male branch.

Inlet outlet DN65 underground hydrant beside an office building
Buried hydrant placed beside an office site outdoor fire loop.

Site fire point placement

Site yard layouts keep the fire loop along approach drives, access lanes, apron edges and service strips, with buried hydrants spaced where the drawing calls for a reachable outdoor point. Each hydrant acts as the isolation point for the branch it feeds and the connection point for a response, so one section can be closed for work without draining the whole loop. Outdoor dust, runoff from paving and occasional spillage settle on exposed stem and cap between rounds, and the inspection cycle wipes the stem, checks the seat and looks for weep around the buried joint before the cover goes back on. Spare bodies sit in the yard store held by bore, variant and end type, so a failed hydrant swaps without a special procurement trip. On paper the bore is one number; in the yard it decides how much water reaches the hose at the pit. Maintenance cycles the body on each visit, clears residue from the stem and cap, and confirms the buried joint stays dry between drills.

One branch closes at a time. The rest of the loop keeps its pressure.

Underground supply notes

Site projects supply hydrants in batches by approach section or building block, and custom specifications are accepted when a riser layout calls for a non-standard outlet arrangement. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity. Before packing, the end connection gets a protector and the valve rests closed; at receiving, match the body to the pit drawing and confirm the end form mates with the buried branch. The source record leaves material, pressure class and certification open, so those fields follow the site fire system specification reviewed at tender rather than a fixed rating printed on the listing.

PortDimension
Listed unit classFire Hydrant
Model referenceSN65, SNW65, SNZ65, SNS65
Bore and portsInlet DN65, Outlet DN65
End connectionFlange Connection, Thread Connection
Working pressure band-
Certification record-
Body composition-
Listed application-
Product categoryFire Hydrant

Hot Tags: Inlet Outlet DN65 Underground Hydrant, China Inlet Outlet DN65 Underground Hydrant manufacturers, above ground fire hydrant, fire hydrant assembly parts, fire hydrant cap, fire hydrant hose connection, fire hydrant outlet, Indoor Fire Hydrant

Send Inquiry

whatsapp

Phone

E-mail

Inquiry