Grooved Ductile Iron Tee Fitting
video

Grooved Ductile Iron Tee Fitting

Ductile iron grooved mechanical tee, saddle clamp branch, QT450-10 to ASTM A536, Pn10/Pn16 with EPDM gasket. Most go into fire sprinkler, water supply and HVAC lines.
We take custom sizes, ISO and ASTM certified. FOB pricing runs US $12-18 per piece, minimum order 1 piece.
Send Inquiry
Product Introduction

Grooved Ductile Iron Tee Fitting

Saddle branch taken off a grooved main

This ductile iron grooved mechanical tee taps a branch off a main through a saddle clamp, used on fire sprinkler, water supply and HVAC lines where a side outlet must be added to an existing or new run. The body sees sprinkler water, supply water and circulating HVAC water, with the EPDM gasket sealing the saddle against the main and the ductile iron shell carrying the listed branch pressure. The tee clamps around the main at the takeoff point, the branch neck connects to the downstream grooved pipe, and the saddle bolts are tightened to seat the gasket before pressure is introduced to the branch line. QT450-10 ductile iron to ASTM A536 forms the saddle body, giving the clamp enough strength to grip the main without deforming its wall, while the EPDM seal handles the water service and ambient exposure recorded for the listing. The saddle clamp mounting and grooved branch are the listed connection forms; the Pn10 and Pn16 ratings cover the sprinkler, supply and HVAC duties described, with size produced to the project's customized requirement. Fire sprinkler, water supply and HVAC are the recorded usage sectors; ISO and ASTM are the listed certification references on the source entry. The listing records the dimensions, end forms and service sectors described in the sections below, and each piece is checked against the order record before it moves to surface inspection and packing.

A saddle tee seats on an intact main. Pipe wall condition at the clamp point is checked before the bolts go on.

Ductile iron grooved mechanical tee saddle clamp, Pn10/Pn16, for fire sprinkler and water supply lines
Ductile iron grooved mechanical tee prepared for sprinkler and supply mains.

QT450-10 ductile iron body with EPDM seal

The wetted surface meets the continuous fluid on the line, while the external shell only sees ambient moisture, occasional spray and the support loads from clips, hangers or bedding. Where mixed metals appear in the catalog family, the buyer confirms which metal contacts the fluid, because the outer shell and the wetted parts can differ on the same entry. The plain metal surface is supplied as formed; any paint, wrapping or extra coating follows the plant's own corrosion practice once the piece enters the line. Wall thickness carries internal pressure and the small external loads imposed during installation, and a casting or surface with visible flaws is set aside before assembly or release rather than mixed into the batch. Where the line carries grit, condensate or repeated thermal cycling, the buyer compares the seat, weld or thread condition at each inspection before the body itself is questioned, because the wear parts renew far cheaper than the casting.

The installation environment sets the finish and the inspection interval, since an indoor plant room, an outdoor rack and a buried trench each expose the body to a different mix of moisture and mechanical handling. Support spacing, clip loads and the local corrosion practice are recorded on the project drawing, and the piece is supplied to match those conditions rather than a one-size finish. Temperature cycling and occasional wetting around equipment connections are accounted for when the body grade and wall are chosen for the listed duty.

Sprinkler contractors batch branch tees by main size. The branch neck matches the downstream takeoff diameter.

The drawing carries the final size.

Clamp saddle and grooved branch connection

The fit-up is checked against the neighboring component before the joint closes: end form, thread pitch or bevel preparation must sit flush with the mating pipe, and a mismatch means an extra adapter, reducer or redo inside the cabinet, skid or trench. End protectors and wrapping stay on until the joint is ready to close, because grit on the thread, bevel or gasket face is the usual reason a fresh joint fails its first inspection. The order sheet records nominal size, wall and end condition, and the shop prepares each piece to those dimensions before surface check and packing. Alignment is checked again at receiving on site, where the end squareness and the mating bore are compared against the spool drawing before the line is closed.

Pn10 and Pn16 rating for sprinkler and water runs

The standard reference recorded on the listing is ISO, ASTM. The working pressure band on record is Pn10 / Pn16. The recorded dimension band is Customized. The listing leaves some descriptive fields open where the source record carries no fixed value, and those entries are marked as such in the table rather than filled in by assumption. The rating is set against maximum pressure with surge included, not average running pressure, so a class picked on steady flow may weep when reversal or a pressure spike arrives on the line.

Branch takeoff check on the sprinkler layout

The record sheet travels with the batch. Each piece is checked for bore, wall, end squareness and surface condition before packing, and the record sheet follows it through the order. The packed batch is marked with the order reference so receiving inspection on site can match each piece to the spool list without opening every crate. Pieces that fail the end or dimension check go back to the shop rather than being mixed into the shipment. Spare pieces for future maintenance are held in the store by size and form, separate from the batch installed on the current run.

A small trial order is accepted where the listing allows. The recorded minimum stands at 1 piece. The listed bracket runs US $12-18 per piece. Buyers usually send the full size list in one request so the batch can be scheduled together and delivered in one shipment rather than split across several production slots. Each piece in the batch carries the same order reference, which lets receiving inspection sort by size without opening every crate. Where a project needs several branches of the same OD and wall, the whole set is ordered together so fabrication does not stop between sections.

Compare the drawing to the listing before commitment, and confirm bore, end form and rating against the project piping specification once the order list is finalized.

RowReading
Standard reference on fileISO, ASTM
Listed service sectorFire sprinkler, water supply, HVAC
Catalog product familyTee
Listed product patternMechanical Tee
Body construction metalQT450-10 Ductile Iron (ASTM A536)
Model or designation on recordXGQT
Bore and dimension bandCustomized
Connection form acceptedSaddle clamp
Working pressure ratingPn10 / Pn16

Hot Tags: Grooved Ductile Iron Tee Fitting, China Grooved Ductile Iron Tee Fitting manufacturers, carbon steel adapter fittings, carbon steel industrial piping components, carbon steel pipe fitting, carbon steel pipe joint fittings, carbon steel process fittings, carbon steel threaded connector fittings

Send Inquiry

whatsapp

Phone

E-mail

Inquiry