Integral Body Above Ground Fire Hydrant
video

Integral Body Above Ground Fire Hydrant

Integral-body outdoor above-ground fire hydrants in Ss100/65 and Ss150/80, inlet DN100/DN150, outlet DN65/DN80, flange connection. Used for substation and industrial yard fire protection.
Customization is accepted and OEM is welcome. FOB price runs from US $65-1,000 per piece, MOQ 30 pieces.
Send Inquiry
Product Introduction

Integral Body Above Ground Fire Hydrant

A one-piece body standing above ground

This integral-body hydrant stands above ground along a substation or industrial yard fire loop, its one-piece body rising from the buried riser at the edge of the paving. The single-piece body keeps the outer shell continuous from base to stem, with fewer assembled seams exposed to outdoor weather, and it stays visible along driveways, apron edges and equipment rows where a buried pit would slow a response. The unit belongs to the above-ground hydrant family rather than the buried cabinet class, and it connects to a buried branch through a base flange. Substation rounds pass the standpipe on every lap, check the cap and outlets, and confirm the body sits plumb in its mounting. The source record leaves listed application open, so the service scope follows the substation fire system specification reviewed at tender. Integral-body construction matters where exposed seams would otherwise collect moisture and residue between inspection rounds.

The body stands as one piece. Fewer seams sit exposed outdoors.

SS model variants and inlet sizing

The model references read Ss100/65 and Ss150/80, the two variants of the SS hydrant range listed on the record. The specification covers DN100 and DN150 on the inlet side, so the larger body carries a bigger inlet bore, and inlet size decides how much water the standpipe can feed to a connected hose. The two variants cover the standard above-ground sizes used around substations and industrial yards, and the site schedule names the variant at each standpipe position. Material carries no assigned value on the listing, and pressure class and certification record are marked open; line rating and any required approval are confirmed against the substation fire system specification reviewed at tender rather than assumed from the body shape. The casing schedule names the variant at each take-off, and maintenance replaces like for like so the branch hydraulic role stays unchanged after a swap.

The inlet runs DN100 or DN150. The two SS variants cover the listed sizes.

Flanged connection at the base

The joint type lists flange connection as the base arrangement. The standpipe bolts through a companion flange on the buried riser with gasket and even torque, a rigid joint that keeps the body upright under outdoor weather and occasional side loads from passing traffic. Flanged assembly lets a crew lift the body for maintenance without cutting the buried branch, and the bolt circle and gasket face follow the riser flange on the project drawing. Where the paving settles around the base, the crew checks that the standpipe remains plumb and that no gap opens under the flange, because a tilted body strains the riser joint over time. A threaded base would need an adapter in this arrangement, so the schedule keeps flange for the above-ground class.

The base bolts down to the riser flange. The body lifts off for maintenance.

Integral body above ground fire hydrant at a substation yard
One-piece hydrant body standing beside an industrial fire loop.

Where the integral body earns its place

Substation and industrial yard layouts keep the fire loop along driveways, apron edges, equipment rows and service lanes, with above-ground hydrants spaced where the drawing calls for a reachable outdoor point. Each standpipe acts as the isolation point for the branch it feeds and the connection point for a response, so a section can be closed for work without draining the whole loop. Outdoor dust, pollen, road salt in winter months and runoff from paving settle on the exposed body between rounds, and the inspection cycle wipes the outlets, checks the stem and looks for weep around the base flange before the cover goes back on. Spare bodies in the store are held by inlet size, outlet size and base end type, so a failed standpipe swaps without a special procurement trip. On a substation apron the standpipe has to be obvious from the approach; buried pits would slow a response that relies on sighting the fire point quickly. The one-piece shell keeps the exposed exterior uninterrupted, which reduces the places where residue and moisture can collect between rounds.

Standpipes space out along the apron. Each one closes its own branch.

Rounds mark the outlets and base flange on each lap, brushing off dust before checking the joint for weep. The one-piece shell keeps the exposed exterior uninterrupted, and fewer assembled seams sit where moisture and residue could collect between rounds. Spare bodies in the store are filed by inlet and outlet size, so a failed standpipe swaps without a special procurement trip.

Supply notes for yard projects

Substation projects supply hydrants in batches by yard section or equipment row, and custom models are accepted when a riser layout calls for a non-standard outlet arrangement. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity. Before packing, the flange face gets a protector and the valve rests closed; at receiving, match the body to the paving drawing and confirm the base mates with the buried riser. The source record leaves material, pressure class and certification open, so those fields follow the substation fire system specification reviewed at tender rather than a fixed rating printed on the listing.

BodyForm
Listed unit classFire Hydrant
Model referenceSs100/65, Ss150/80
Bore scheduleDN100/DN150
End connectionFlange Connection
Working pressure band-
Certification record-
Body composition-
Listed application-
Product categoryFire Hydrant

Hot Tags: Integral Body Above Ground Fire Hydrant, China Integral Body Above Ground Fire Hydrant manufacturers, above ground fire hydrant, fire hydrant, fire hydrant assembly parts, fire hydrant coupling, fire hydrant metal valve body, fire hydrant repair parts

Send Inquiry

whatsapp

Phone

E-mail

Inquiry