Indoor Threaded Fire Hydrant DN65
video

Indoor Threaded Fire Hydrant DN65

Indoor fire hydrant in Sn65, SNW65, SNZ65 and SNS65, DN65, flange or thread ends. Commonly used for indoor commercial building fire protection.
Custom models are accepted, FOB pricing runs US $5-70 per piece, min. order 30 pieces; OEM welcome.
Send Inquiry
Product Introduction

Indoor Threaded Fire Hydrant DN65

Set into the commercial mall corridor

This indoor hydrant serves the interior of a commercial building, set into a cabinet along a mall corridor, lobby edge or common area access point. The indoor class of unit stays dry between drills, paired with a hose roll and nozzle parked in the same box, and it feeds vertical riser water rather than an outdoor standing main. Listed application on the source record is commercial building fire protection, covering the indoor hydrant connections of shops, public walkways and shared interior spaces. Cabinets repeat along the corridor layout at the intervals the fire system drawing specifies, each box holding its matched hose and nozzle so the pair stays together through a fast response. Public rounds check each cabinet door on every lap, and the hydrant inside gets the same inspection cycle as the hose roll beside it. Commercial layouts separate shop fronts, seating rows, service corridors and stairwell approaches, and each branch keeps its own hydrant at the take-off shown on the fire drawing.

The hydrant stays in the cabinet. The hose and nozzle share the same box.

DN65 body and listed model family

The specification lists a DN65 bore, matching a sixty-five-millimetre branch off the building riser, and bore size decides flow through the branch, so it should align with the hose or feed line the cabinet serves on the corridor layout. Model references read Sn65, Snw65, Snz65 and Sns65, the four-variant indoor hydrant family carried on the listing. The base Sn65 is the standard indoor body; Snw65 adds a regulating function, Snz65 uses a rotary arrangement, and Sns65 carries a double-outlet configuration. The cabinet schedule names the variant at each take-off, and maintenance replaces like for like so the branch hydraulic role stays unchanged after a swap. Material carries no assigned value on the listing, and pressure class and certification record are marked open; line rating and any required approval are confirmed against the commercial fire system specification reviewed at tender rather than assumed from the body shape.

The bore runs DN65. The four variants cover the listed indoor hydrant roles.

Threaded and flanged end assemblies

The joint type lists flange connection and thread connection as end options. Threaded ends screw onto a male connection where standard wrenches break the joint open, suited to smaller branches where a flange would crowd the cabinet recess, and this listing carries the threaded arrangement as one of the two end forms. Flanged ends bolt through a companion flange on the riser take-off with gasket and even torque, a rigid joint suited to larger branches where the crew wants a repeatable seal that opens and reseals during maintenance. The end form follows how the commercial riser was built, and the corridor schedule states flange or thread per cabinet; a mixed match needs an adapter inside the wall recess, which crowds the box and adds another seal face to inspect. Before the joint closes, the sealing face gets wiped clean, because grit left in the bore or on the thread is the usual reason a fresh connection weeps after the first pressure test.

Thread screws onto the male take-off. Flange bolts to the companion face.

Indoor threaded fire hydrant DN65 in a commercial mall corridor
Indoor hydrant cabinet placed along a commercial building walkway.

Indoor service in public buildings

Public building layouts place cabinets along corridors, lobby edges, stairwell approaches and room access points, where a short hose reach covers the nearest seating row, shop front or doorway. Each hydrant acts as the isolation point for the branch it feeds and the connection point for a response, so one section can be closed for work without draining the whole riser. Indoor dust, panel trim residue and occasional cleaning spillage settle on exposed hydrant faces between rounds, and the inspection cycle wipes the stem, checks the seat and looks for weep around the connection before the roll returns to the cabinet. Spare bodies sit in the building store held by bore, variant and end type, so a failed hydrant swaps without a special procurement trip. On paper the bore is one number; in the corridor it decides how much water reaches the hose at the cabinet. Maintenance cycles the body on each visit, clears residue from the stem and cap, and confirms the connection stays dry between drills.

One branch closes at a time. The rest of the riser keeps its pressure.

Order notes for building supply

Commercial projects supply hydrants in batches by floor or wing, and custom models are accepted when a riser layout calls for a non-standard outlet arrangement. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity. Before packing, the end connection gets a protector and the valve rests closed; at receiving, match the body to the cabinet drawing and confirm the end form mates with the riser take-off. The source record leaves material, pressure class and certification open, so those fields follow the commercial fire system specification reviewed at tender rather than a fixed rating printed on the listing.

GroupContent
Listed unit classIndoor Fire Hydrant
Model referenceSn65/Snw65/Snz65/Sns65
Bore scheduleDN65
End connectionFlange Connection, Thread Connection
Working pressure band-
Certification record-
Body composition-
Listed applicationCommercial Building Fire Protection
Product categoryFire Hydrant

Hot Tags: Indoor Threaded Fire Hydrant DN65, China Indoor Threaded Fire Hydrant DN65 manufacturers, above ground fire hydrant, Corrosion resistant Outdoor Fire Hydrant, Durable Cast Iron Indoor Fire Hydrant, fire hydrant coupling, fire hydrant distribution system, fire hydrant flange connection

Send Inquiry

whatsapp

Phone

E-mail

Inquiry