Pressure Regulating Indoor DN65 Hydrant
Custom models are accepted, FOB pricing runs US $5-70 per piece, min. order 30 pieces.
Pressure Regulating Indoor DN65 Hydrant
Inside the substation fire hall
This indoor hydrant serves the interior of a substation or industrial building, mounted on the riser take-off in a cabinet along an equipment room wall, corridor or control room approach. The indoor class of unit stays dry between drills, paired with a hose roll and nozzle in the same cabinet, and it feeds vertical riser water rather than an outdoor standing main. The regulating function adjusts pressure along the branch, keeping delivery within the range the indoor hose run expects when a response or a drill opens the connection. Listed application on the source record is substation fire protection, covering the indoor hydrant connections of electrical and industrial premises. Cabinets repeat along the room layout at the intervals the fire system drawing specifies, each box holding its matched hose and nozzle so the pair stays together through a fast response. Indoor rounds check each cabinet door, and the hydrant inside gets the same inspection cycle as the hose roll beside it.
The hydrant sits in the cabinet. The hose roll parks beside it in the same box.
Regulating function on the DN65 body
The specification lists a DN65 bore, matching a sixty-five-millimetre branch off the building riser, and bore size decides flow through the branch, so it should align with the hose or feed line the cabinet serves on the room layout. The regulating role keeps branch pressure steady across the hose run, which matters where the riser feeds several indoor take-offs at different floor levels. Model references read Sn65, Snw65, Snz65 and Sns65, the four-variant indoor hydrant family carried on the listing. The base Sn65 is the standard indoor body; Snw65 adds the regulating function, Snz65 uses a rotary arrangement, and Sns65 carries a double-outlet configuration. Material carries no assigned value on the listing, and pressure class and certification record are marked open; line rating and any required approval are confirmed against the substation fire system specification reviewed at tender rather than assumed from the body shape.
The bore runs DN65. The regulating function steadies branch pressure.
Model variants and end connection types
The joint type lists flange connection and thread connection as end options. Flanged ends bolt through a companion flange on the riser take-off with gasket and even torque, a rigid joint suited to larger branches where the crew wants a repeatable seal that opens and reseals during maintenance. Threaded ends screw onto a male connection where standard wrenches break the joint open, suited to smaller branches where a flange would crowd the cabinet recess. The end form follows how the industrial riser was built, and the room schedule states flange or thread per cabinet; a mixed match needs an adapter inside the wall recess, which crowds the box and adds another seal face to inspect. Before the joint closes, the sealing face gets wiped clean, because grit left in the bore or on the thread is the usual reason a fresh connection weeps after the first pressure test.
Flange bolts to the companion face. Thread screws onto the male take-off.

Indoor placement in industrial buildings
Industrial layouts separate transformer bays, switchgear rooms, battery areas and control rooms, and each branch keeps its own hydrant at the take-off shown on the fire drawing. The hydrant on those branches acts as the isolation point for maintenance and the connection point for a response, so one section can be closed while work proceeds on another without draining the whole building riser. Indoor dust, occasional moisture from ventilation and cleaning spillage settle on exposed hydrant faces between rounds, and the inspection cycle wipes the stem, checks the seat and looks for weep around the connection before the roll returns to the cabinet. Spare bodies sit in the industrial store held by bore, variant and end type, so a failed hydrant swaps without a special procurement trip. On paper the bore is one number; in the room it decides how much water reaches the hose at the cabinet. Maintenance cycles the body on each visit, wipes the stem and seat, and confirms the connection stays dry between drills.
One branch closes at a time. The rest of the riser keeps its pressure.
Rounds wipe the stem and seat at each visit, clearing residue before confirming the branch connection stays dry. The indoor schedule names the Sn variant at each take-off, and maintenance replaces like for like after a swap.
Indoor hydrant supply notes
Industrial projects supply hydrants in batches by room or building section, and custom models are accepted when a riser layout calls for a non-standard outlet arrangement. A trial order can start with a small lot, and the price bracket and delivery window follow the quotation and the ordered quantity. Before packing, the end connection gets a protector and the valve rests closed; at receiving, match the body to the cabinet drawing and confirm the end form mates with the riser take-off. The source record leaves material, pressure class and certification open, so those fields follow the substation fire system specification reviewed at tender rather than a fixed rating printed on the listing.
| Piece | Marking |
|---|---|
| Listed unit class | Indoor Fire Hydrant |
| Model reference | Sn65/Snw65/Snz65/Sns65 |
| Bore schedule | DN65 |
| End connection | Flange Connection, Thread Connection |
| Working pressure band | - |
| Certification record | - |
| Body composition | - |
| Listed application | Substation Fire Protection |
| Product category | Fire Hydrant |