Stainless Steel Flanged Check Valve
Custom orders are accepted, FOB pricing runs US $14.49 per piece, min. order 100 pieces. OEM is welcome.
Stainless Steel Flanged Check Valve
Compressed air mains feeding tool and process drops
Reverse flow on this line is what the check guards against; the body mounts at compressed air systems and process piping, opening as forward flow passes and closing the moment the direction flips. Near the discharge point the valve leaves enough clearance for the disc to travel and for a wrench on the flange bolts; cramped skids often force a wafer body where a flanged one would not fit. Line size is set from flow calculations, and the class is matched to peak pressure including any trip surge before the valve is committed. The spare matches the installed main.
The listed size band and working rating are shown in the table below for reference before selection.

Stainless body against moisture and oil carry-over
The material sees both the pumped or flowing fluid and the occasional external spray in the plant; buyers match the body metal to the most aggressive fluid on the line rather than the cleanest sample. Where the duty carries grit or condensate, crews look at the seat first, since a worn seat shows up as a weep after shut-down and the body itself often still has service left in it. The metal surface stays plain as supplied; any paint, wrapping or external coating follows the plant's own corrosion practice once the piece enters the line. Body wall thickness carries internal pressure and the small external loads from clips or supports, and a casting with surface flaws is rejected before assembly reaches the seat. In mixed-material listings the buyer confirms which metal contacts the fluid, because the external shell and the wetted parts can differ on the same entry. The body metal is matched to the most aggressive fluid expected on the run rather than the cleanest sample, because wetted surfaces see pumped product continuously while the shell only meets ambient moisture and occasional spray during access.
Flanged or wafer ends on air receiver outlets
Connection on this entry is Flanged, Wafer. A wafer body needs only the two adjacent line flanges to clamp it in place, and a flanged body adds its own ring to the mating flange. The spool list decides which form ships, so crews do not adapt a wafer stub onto a threaded or welded run on site.
| Reference | Measure |
|---|---|
| Model reference on the listing | DN50-DN200 |
| Size band the listing spans | DN50-DN200 |
| Listed service sector for the valve | Industrial Usage, Water Industrial Usage, Household Usage |
| Approval reference on the entry | ANSI |
| How the ends join the line | Flanged, Wafer |
| Construction metal of the housing | Stainless Steel |
| What the valve family is listed as | Wafer Check Valve |
| Listed type of the assembly | Wafer Check Valve |
| Pressure class the body carries | Pn10, Pn16 |
Seat closure on compressor shut-down pulses
Under forward flow the disc lifts off its seat and the bore opens; flow pressure holds it open while the line runs. When the pump trips, pressure eases off or the downstream side pushes back, the disc returns against the seat and blocks reverse movement. Over many cycles the hinge and guide surfaces take the load, and these are the parts that show first signs of wear. A disc that closes too slowly builds a pressure wave through the system; one that slams shut can pulse the adjacent piping, and the seat style sets how gently the return happens. Maintenance crews note the bore, end form and rating when a spare is ordered, so the replacement matches the line rather than a generic stock piece. Over repeated cycles the hinge surfaces and guide faces take the brunt of the movement, and these parts show wear before the housing does, so a rattle or chatter should be traced to pin, guide or seat before any decision to replace the casting. The setting follows the project drawing.
The store keeps sealing parts grouped by bore and end form. Inserts, pins and guides wear first, and these are held for the busiest sizes instead of a full spare valve for every diameter. A rattle usually means grit on the seat or a worn pin, and early attention avoids a weep after trip-off. Castings that have held pressure rarely need replacement once sealing parts are renewed.
Bore is chosen from the listed diameter band against calculated line flow, and the pressure class is matched to the maximum pressure the line reaches during start-up, trip and shut-down rather than its steady running figure. Buyers note end form, seat compound and rating when a spare is ordered, so the replacement matches the installed main instead of a generic stock piece. Notes go in the maintenance record.
Before the valve enters the run, crews match the end type to the adjacent flange or weld preparation and check that the moving element travels freely between the closed and open stops. Sealing faces are wiped clean of grit, and thread or flange protectors stay on until the joint is ready to close, so no debris lodges between seat and closure during commissioning. The first pressure test after fit-up reveals any weep early, before the line is handed over to operation.
Seat problems surface on the initial test before any body weakness appears, and the record should note bore, end form and rating when the sealing part is replaced so the spare matches the installed main.
Air system spares by diameter and ANSI class
Bore DN50-DN200 under rating Pn10, Pn16 is the listed range; confirm end form, seat type and pressure class against the project drawing before ordering. The listing records ANSI as the standard reference. A trial order can start with one piece where the listing allows; the price bracket and delivery window are settled with the quotation once bore, end form and quantity are confirmed.
Hot Tags: Stainless Steel Flanged Check Valve, China Stainless Steel Flanged Check Valve manufacturers, anti backflow valve, axial check valve, Brass Wafer Check Valve, high durability valve, hydraulic check valve, Stainless Steel Lift Check Valve
You Might Also Like
Send Inquiry