PTFE Lined Stainless Steel Check Valve
Custom orders are accepted, FOB pricing runs US $14.49 per piece, min. order 100 pieces.
PTFE Lined Stainless Steel Check Valve
Pump suction lines feeding corrosive process duties
Crews locate this check valve at pump suction and corrosive process lines; its job is to let the line flow one way and shut the door the moment pressure tries to come back. Near the discharge point the valve leaves enough clearance for the disc to travel and for a wrench on the flange bolts; cramped skids often force a wafer body where a flanged one would not fit. Line size is set from flow calculations, and the class is matched to peak pressure including any trip surge before the valve is committed. The spare matches the installed main.
The listed size band and working rating are shown in the table below for reference before selection.

Stainless body with PTFE fluid-side lining
Housing metal on this entry is Stainless Steel; it carries internal pressure, stem or hinge loads and the occasional wetting from the surrounding line. The PTFE lining over the sealing face contacts the fluid, and the closure follows the lined wafer check protecting the metal body from process fluid noted on the listing. Seat and body are selected together, since the fluid that wears the insert can also attack the shell. External surface stays plain as delivered; paint or wrapping follows the plant's corrosion practice after fit-up. Wall thickness carries internal pressure and small loads from clips and supports, and castings with surface flaws are rejected before the seat is fitted. Mixed-material entries require confirming which metal contacts the fluid, since shell and wetted parts can differ. The body metal is matched to the most aggressive fluid expected on the run rather than the cleanest sample, because wetted surfaces see pumped product continuously while the shell only meets ambient moisture and occasional spray during access.
Wafer end between suction header flanges
Connection on this entry is Wafer. A wafer body needs only the two adjacent line flanges to clamp it in place, and a flanged body adds its own ring to the mating flange. The spool list decides which form ships, so crews do not adapt a wafer stub onto a threaded or welded run on site.
| Tag | Specimen |
|---|---|
| Model reference on the listing | DN50-DN200 |
| End form matched to the spool | Wafer |
| Product family in the catalog | Wafer Check Valve |
| Duty the piece is assigned to | Industrial Usage, Water Industrial Usage, Household Usage |
| Standard record attached to the listing | ANSI |
| Size band the listing spans | DN50-DN200 |
| What the body is cast or made from | Stainless Steel |
| Working rating across the bore | Pn10, Pn16 |
| What the valve family is listed as | Wafer Check Valve |
Lined disc and seat against chemical contact
The disc rides open while forward flow passes, and gravity or line pressure returns it to the seat once flow stops or reverses. A slow-closing disc lets a pressure wave build, while a guided closure keeps that wave modest; seat leakage after shut-down usually means a worn insert, trapped grit or a hanging disc guide, not a failed housing. When the check chatters after long service, crews clean the sealing face, check the guide for grit and turn over the insert before condemning the body. A worn pin or guide face is the usual cause of a rattle, and these parts renew far cheaper than a housing replacement. The pressure class on the listing is chosen against peak surge, so a class picked on average pressure may weep when reversal arrives. Over repeated cycles the hinge surfaces and guide faces take the brunt of the movement, and these parts show wear before the housing does, so a rattle or chatter should be traced to pin, guide or seat before any decision to replace the casting. The setting follows the project drawing.
The store keeps sealing parts grouped by bore and end form. Inserts, pins and guides wear first, and these are held for the busiest sizes instead of a full spare valve for every diameter. A rattle usually means grit on the seat or a worn pin, and early attention avoids a weep after trip-off. Castings that have held pressure rarely need replacement once sealing parts are renewed.
Bore is chosen from the listed diameter band against calculated line flow, and the pressure class is matched to the maximum pressure the line reaches during start-up, trip and shut-down rather than its steady running figure. Buyers note end form, seat compound and rating when a spare is ordered, so the replacement matches the installed main instead of a generic stock piece. Notes go in the maintenance record.
Before the valve enters the run, crews match the end type to the adjacent flange or weld preparation and check that the moving element travels freely between the closed and open stops. Sealing faces are wiped clean of grit, and thread or flange protectors stay on until the joint is ready to close, so no debris lodges between seat and closure during commissioning. The first pressure test after fit-up reveals any weep early, before the line is handed over to operation.
Seat problems surface on the initial test before any body weakness appears, and the record should note bore, end form and rating when the sealing part is replaced so the spare matches the installed main.
Process spares selected by bore and rating
The listed bore band is DN50-DN200 and the pressure band is Pn10, Pn16; bore, end form, seat and class are checked against the piping drawing before commitment. The listing records ANSI as the standard reference. A trial order can start with one piece where the listing allows; the price bracket and delivery window are settled with the quotation once bore, end form and quantity are confirmed.
Hot Tags: PTFE Lined Stainless Steel Check Valve, China PTFE Lined Stainless Steel Check Valve manufacturers, air check valve, axial check valve, inline flow check device, Oil Check Valve, Socket Weld Check Valve, valve system check component
You Might Also Like
Send Inquiry