Iron Grooved Cross Fire Fitting
video

Iron Grooved Cross Fire Fitting

Grooved equal cross for fire protection, cast iron body finished red, DN80 to DN250, rated 1.6MPa to GB5135.11 and Awwa C606. Most end up on street fire protection and HVAC circulating water lines.
We stock the common sizes and ship out in wooden cases. FOB pricing runs US $12-20 per piece, minimum order 1 piece.
Send Inquiry
Product Introduction

Iron Grooved Cross Fire Fitting

Four-way branch on fire protection and HVAC loops

This grooved equal cross splits one run into four branches on fire protection and HVAC circulating water lines, where a four-way tee pattern is required at a riser or manifold point. The body sees fire-protection water and circulating HVAC water, along with the ambient moisture of plant rooms and street-side fire service installations where the grooved connection is exposed after install. The cross mounts on fire risers, sprinkler manifolds and HVAC circulation headers, with grooved couplings locking each branch to the neighboring pipe and the piece aligned square before the coupling is tightened. The cast iron body carries the listed 1.6MPa working pressure and the small external loads from clips and supports, finished in red protective coating for the fire service appearance expected on the installation. Grooved ends mate with grooved couplings and gasket seals, and the DN80 to DN250 size band covers the common street fire protection and circulating water diameters encountered on standard projects. Fire protection and HVAC are the recorded usage sectors; GB5135.11 and Awwa C606 are the listed certification references on the source entry. The listing records the dimensions, end forms and service sectors described in the sections below, and each piece is checked against the order record before it moves to surface inspection and packing.

Street fire crews match groove lip to coupling. A loose groove shows as a weep after pressure fills the main.

Iron grooved equal cross DN80 to DN250 rated 1.6MPa for fire protection and HVAC water lines
Grooved cross fitting prepared for fire protection and circulating water lines.

Cast iron body with red protective finish

The wetted surface meets the continuous fluid on the line, while the external shell only sees ambient moisture, occasional spray and the support loads from clips, hangers or bedding. Where mixed metals appear in the catalog family, the buyer confirms which metal contacts the fluid, because the outer shell and the wetted parts can differ on the same entry. The plain metal surface is supplied as formed; any paint, wrapping or extra coating follows the plant's own corrosion practice once the piece enters the line. Wall thickness carries internal pressure and the small external loads imposed during installation, and a casting or surface with visible flaws is set aside before assembly or release rather than mixed into the batch. Where the line carries grit, condensate or repeated thermal cycling, the buyer compares the seat, weld or thread condition at each inspection before the body itself is questioned, because the wear parts renew far cheaper than the casting.

The installation environment sets the finish and the inspection interval, since an indoor plant room, an outdoor rack and a buried trench each expose the body to a different mix of moisture and mechanical handling. Support spacing, clip loads and the local corrosion practice are recorded on the project drawing, and the piece is supplied to match those conditions rather than a one-size finish. Temperature cycling and occasional wetting around equipment connections are accounted for when the body grade and wall are chosen for the listed duty.

The cross goes on the riser where four branches leave at once. Layout space matters before the coupling closes.

The order reference follows every packed piece.

Grooved ends pulled onto the coupling lips

The fit-up is checked against the neighboring component before the joint closes: end form, thread pitch or bevel preparation must sit flush with the mating pipe, and a mismatch means an extra adapter, reducer or redo inside the cabinet, skid or trench. End protectors and wrapping stay on until the joint is ready to close, because grit on the thread, bevel or gasket face is the usual reason a fresh joint fails its first inspection. The order sheet records nominal size, wall and end condition, and the shop prepares each piece to those dimensions before surface check and packing. Alignment is checked again at receiving on site, where the end squareness and the mating bore are compared against the spool drawing before the line is closed.

Size band and 1.6MPa working pressure

The standard reference recorded on the listing is GB5135.11, Awwa C606. The working pressure band on record is 1.6MPa. The recorded dimension band is DN80 to DN250. The listing leaves some descriptive fields open where the source record carries no fixed value, and those entries are marked as such in the table rather than filled in by assumption. The rating is set against maximum pressure with surge included, not average running pressure, so a class picked on steady flow may weep when reversal or a pressure spike arrives on the line.

Assembly check on the fire riser takeoff

The record sheet travels with the batch. Each piece is checked for bore, wall, end squareness and surface condition before packing, and the record sheet follows it through the order. The packed batch is marked with the order reference so receiving inspection on site can match each piece to the spool list without opening every crate. Pieces that fail the end or dimension check go back to the shop rather than being mixed into the shipment. Spare pieces for future maintenance are held in the store by size and form, separate from the batch installed on the current run.

A small trial order is accepted where the listing allows. The recorded minimum stands at 1 piece. The listed bracket runs US $12-20 per piece. Buyers usually send the full size list in one request so the batch can be scheduled together and delivered in one shipment rather than split across several production slots. Each piece in the batch carries the same order reference, which lets receiving inspection sort by size without opening every crate. Where a project needs several branches of the same OD and wall, the whole set is ordered together so fabrication does not stop between sections.

Compare the drawing to the listing before commitment, and confirm bore, end form and rating against the project piping specification once the order list is finalized.

SectionDetail
Catalog product familyCross
Listed product patternGrooved Cross
Body construction metalIron
Model or designation on record-
Bore and dimension bandDN80 to DN250
Connection form acceptedGrooved
Working pressure rating1.6MPa
Standard reference on fileGB5135.11, Awwa C606
Listed service sectorFire protection and HVAC

Hot Tags: Iron Grooved Cross Fire Fitting, China Iron Grooved Cross Fire Fitting manufacturers, carbon steel adapter fittings, carbon steel industrial joint fittings, carbon steel plug fittings, carbon steel process fittings, pipe fitting kit, Seamless Carbon Steel Elbow

Send Inquiry

whatsapp

Phone

E-mail

Inquiry