Ductile Iron Flanged Y Type Strainer
We make about 100,000 sets a year, lead time near 20 days. CE certified, MOQ from 1 piece, FOB from US $28 per piece.
Ductile Iron Flanged Y Type Strainer
Where the Y branch sits on a fire suction main
The listed duty is fire service, and this Y type strainer bolts onto pump suction and fire service lines, where the angled branch catches scale, grit and weld debris before it reaches the pump impeller or any downstream equipment on the header. On a fire pump header the fitting is placed ahead of the suction inlet, so any scale, weld bead or loose pipe grit drops into the screen instead of entering the impeller. Access around the branch matters: the angled pocket needs room to swing open for screen removal, and the flange bolts stay clear of the branch cover. Bore follows calculated suction flow, and the class is checked against the highest pressure reached during start-up and trip rather than steady running pressure. The setting follows the project drawing.
Size and rating entries appear in the table further down the page for comparison with the fire main.

QT450 ductile iron body with 304 stainless screen
The housing is listed as Ductile Iron (QT450), the casting that carries internal suction pressure and the occasional external load from supports along the main. Inside the angled pocket a 304 stainless steel screen sits against the flow, trapping solids while water passes through the perforations. Body material is matched to the water and any mild chemical carry-over expected on the line, rather than to the cleanest sample drawn from the tap. The metal surface stays plain as supplied; any paint or external coating follows the plant's own corrosion practice once the piece enters the line. Body wall thickness carries internal pressure and small loads from clips or supports, and a casting with surface flaws is rejected before the screen and branch cover are fitted. The screen is the first wear item, and buyers keep a spare screen for the busiest size rather than stocking a complete spare fitting.
Flanged ends bolted to pump suction and fire lines
The connection listed is Flanged End. Raised-face flanges bolt to matching line flanges through a gasket, and the joint is centered before the bolts go cross-sequence so the seal compresses evenly around the bore. End type follows the spool drawing; a mismatch means an adaptor or reducer that delays the fire main joint. The flange rating and face are checked against adjacent fittings on the same header.
| Record | Nominal |
|---|---|
| What the fitting family is listed as | Y-Type Strainer |
| What the body is cast from | Ductile Iron (QT450) |
| Model reference on the listing | GL41H-16 |
| Nominal bore range covered | DN50–DN300 (2"–12") |
| How the ends join the line | Flanged End |
| Pressure class the body carries | Pn16 (1.6 MPa) |
| Standard record attached to the entry | CE |
| Listed service sector for the fitting | Fire Service |
| Product family in the catalog | Y-Type Strainer |
Screen removal and drain plug cleaning in service
Flow enters the straight bore, turns into the angled branch, and passes through the stainless screen before leaving toward the pump; solids settle against the screen mesh and collect in the lower pocket below the flow axis, where they stay until the cover is opened for rinsing. The branch cover unbolts to pull the screen out for rinsing or replacement, and a drain plug at the low point lets collected sludge flush out before the cover goes back on. Mesh size is chosen against the largest particle the downstream equipment can tolerate, and a clogged screen shows up as a drop in suction pressure rather than a sudden failure. Over repeated clean-outs the branch cover gasket and screen seal are the parts that wear first, and these are renewed before the casting shows any sign of damage. A worn screen or scored seal is replaced rather than lapped back into shape, and the casting itself keeps service once the screen and gasket are renewed. The spare matches the installed main.
Renewal parts follow the screen and branch cover rather than the shell. Screens, cover gaskets and drain plug seals are stocked for the most cycled diameters, and the gasket is renewed before a weep reaches the flange joints. At each scheduled inspection the screen face is wiped clean and checked for holes or trapped grit, and any permanent set in the seal is renewed before the next fire season. The body casting keeps pressure after the screen and gasket are rebuilt, provided the hydrostatic test still holds.
Bore is chosen from the listed diameter band against calculated suction flow, and the pressure class is matched to the maximum pressure the line reaches during start-up, trip and shut-down rather than its steady running figure. Buyers note end form, screen mesh and rating when a spare is ordered, so the replacement matches the installed main instead of a generic stock piece. Notes go in the maintenance record.
Before the fitting enters the run, crews match the flange to the adjacent pipe and check that the screen seats square inside the branch pocket. Sealing faces are wiped clean of grit, and protectors stay on until the joint is ready to close, so no debris lodges between screen and cover during fit-up. The first pressure test after fit-up reveals any weep early, before the line is handed over to operation.
A blocked screen shows up on the suction gauge before any pump damage appears, so maintenance attention goes to the mesh, the cover gasket and the drain plug before the casting itself is questioned or replaced on the header.
Sizing the strainer from DN50 through DN300
Across DN50–DN300 (2"–12") the rating sits at Pn16 (1.6 MPa); the drawing should be checked for bore, flange end and screen mesh before the order is cut. The listing records CE as the standard reference. One piece starts the order; the price bracket and delivery window go with the quotation once bore, flange end and quantity are confirmed.
Hot Tags: Ductile Iron Flanged Y Type Strainer, China Ductile Iron Flanged Y Type Strainer manufacturers, Class 150 industrial gate valve for water supply, flanged knife gate valve, gate valve, gate valve body, gate valve sealing kit, wastewater gate valve