Cast Iron Flanged Y Pipeline Strainer
video

Cast Iron Flanged Y Pipeline Strainer

Cast iron flanged Y strainer, epoxy blue inside and out, flanged DIN/GB, DN40 to DN300 at Pn16 (1.6 MPa) / Pn25. Most go onto industrial water pipelines for pump protection.
We pack in wooden cases. FOB pricing runs US $6.8-9.5 per piece, minimum order 200 pieces.
Send Inquiry
Product Introduction

Cast Iron Flanged Y Pipeline Strainer

This cast iron flanged Y strainer protects industrial water pipelines from grit that would otherwise score pump impellers and meters. The CI-YS-EPOXY body carries a blue epoxy finish inside and out, covering DN40 to DN300 with DIN or GB flanged ends, rated Pn16 (1.6 MPa) or Pn25, for industrial water service. The certification field on the record is open for confirmation per order. The bracket runs USD $6.8 to $9.5 per piece, with a two-hundred-piece minimum order, and units pack in wooden cases.

Catching grit before it reaches pump impellers and meters

Pump and meter protection is the main job for this Y strainer. Industrial water mains carry sand, scale and pipe debris that would otherwise travel straight to the impeller, seal face or meter mechanism downstream. The strainer goes in ahead of that equipment, with the Y branch pocket catching particles before they enter the protected unit. Water treatment intakes, cooling circulation loops and utility distribution mains all place this kind of protection at pump suction and meter taps. Where the line feeds a turbine, boiler feed or heat exchanger, the screen keeps scale and weld residue off delicate surfaces. A Y pattern keeps flow resistance low compared with a vertical basket chamber, which suits large-flow water mains where pressure drop matters. Crews on such jobs usually log a clean differential pressure at commissioning, so later readings above that baseline show the screen needs attention. On a cooling loop feeding a condenser or chiller, the same strainer keeps rust and casting scale from blocking narrow tube passes that would otherwise require a manual decoking shutdown to clear.

Grit caught upstream never reaches the impeller, and the screen takes the first hit.

Y branch pocket and the removable screen inside

The body forms a Y at an angle to the main run, with the branch pocket holding the removable screen cartridge. Flow follows the main bore while particles larger than the mesh opening fall into the angled pocket against the screen face. The screen cartridge comes out through the branch cover once the fasteners are taken off, so collected debris can be flushed or shaken free before the cartridge goes back in. The branch cover seats on a gasketed face, and cover bolts come up in the same diagonal pattern as a standard flange joint. A rim on the cartridge locates against the body ledge, preventing unfiltered flow from bypassing the screen around the edge. On larger sizes the cover and screen may be heavy enough that a second pair of hands helps during removal and replacement. The listing carries model reference CI-YS-EPOXY, listed under product type Strainer. The angled pocket gives collected grit a gravity settling point below the flow path, so coarse particles do not sit against the mesh face and restrict flow the way a horizontal screen would over the same running time. Pocket points downward.

RowFact
Model referenceCI-YS-EPOXY
Certification record-
Product familyY Strainer
End connection formFlanged (DIN / GB)
Stated serviceIndustrial water pipelines
Nominal size rangeDN40 to DN300
Body and seal materialCast Iron
Listed product categoryStrainer
Listed pressure classesPn16 (1.6 MPa) / Pn25

Cast iron body finished in blue epoxy

Cast iron is the body material recorded on the source table. The casting handles standard industrial water service and the pressure classes listed, and the blue epoxy finish applied inside and out gives the surface a barrier against rust and wet ambient conditions. The internal epoxy also keeps loose casting scale from shedding into the water line, which matters on mains feeding equipment with close tolerances. Where the line carries corrosive wastewater or chemical dosing, the body material should be checked against the fluid before ordering, since cast iron suits ordinary water rather than aggressive chemical service. The casting surface is inspected for sand pockets and flashes before the epoxy coat goes on, and the finished body is checked for coating coverage on the bore and faces. The blue finish also makes the strainer easy to identify on the water main during routine walk-downs, and any chip in the coating shows up quickly against the dark exposed iron beneath. A spare cartridge is held in the maintenance stockroom for a quick swap during a brief outage.

CI-YS-EPOXY cast iron Y type strainer with blue epoxy and DIN GB flanged ends
Cast iron Y strainer with blue epoxy finish on an industrial water main.

DIN and GB flanged ends on industrial water mains

End connections are flanged in DIN or GB pattern, matched to the companion flange on the existing water main. Pressure classes listed on the record are Pn16 (1.6 MPa) and Pn25, aligned with common industrial water and mains ratings. Sizes DN40 to DN300 cover medium suction connections through larger distribution branches, and the strainer diameter follows the line size on the spool drawing. The stated use field reads Industrial water pipelines. Before dispatch, workshop staff verify flange hole spacing and bore, check the epoxy finish, fit and inspect the screen, then pack the unit in wooden cases. On long-running mains, spare cartridges stay on site where shutdown windows are short, and the first cleaning is scheduled against the commissioning baseline. Flange drilling is checked against the companion flange on the project drawing before the body is packed, because a mismatch between the DIN or GB pattern and the existing mating face would delay the fit-up until a replacement could be brought to site. On utility mains feeding meters and small turbines, the strainer is installed with the branch pocket facing downward so collected grit settles into the removable screen rather than being swept back into the main bore when flow slows or reverses during a pump switchover.

Hot Tags: Cast Iron Flanged Y Pipeline Strainer, China Cast Iron Flanged Y Pipeline Strainer manufacturers, 304 316L Stainless Steel Industrial Filtration Device, alkali resistant strainer, debris removal strainer, hvac water strainer, pipeline maintenance components, valve protection strainer

Send Inquiry

whatsapp

Phone

E-mail

Inquiry