Ductile Iron Pipe Repair Clamp DN65
video

Ductile Iron Pipe Repair Clamp DN65

Ductile iron pipe repair clamp, QT450-10 with blue epoxy, split two-piece or full wrap, DN65 to DN1200 at Pn10/Pn16 (up to PN25). Most go out for emergency repair on tap water, sewage and industrial lines.
We supply these in bulk for utility crews. FOB pricing runs US $0.8-1 per piece, minimum order 1,000 pieces.
Send Inquiry
Product Introduction

Ductile Iron Pipe Repair Clamp DN65

Split two-piece and full-wrap designs

This ductile iron repair clamp is the fitting line crews carry for emergency leak stops on live water mains. It wraps split two-piece or full wrap around the pipe in QT450-10 with a blue epoxy coat, DN65 to DN1200, rated Pn10 and Pn16 up to PN25. Most pieces go out for emergency repair on tap water, sewage and industrial lines.

Ductile iron body with blue epoxy coat

The split two-piece design opens around the pipe without removing a section of main, so crews can seal a leak while the line stays in service. The full-wrap version covers a longer damaged zone where corrosion or a split runs along the barrel. The QT450-10 ductile iron body provides rigidity under bolt tension, and the blue epoxy coat protects the casting from soil moisture and contact with the carried water. An elastomer gasket lines the inside of the clamp, compressing against the pipe exterior when the housing bolts are drawn evenly to seal the weep without draining the main. Pressure ratings cover Pn10 and Pn16, with capacity up to PN25 for higher-pressure repair work.

Each clamp is inspected for casting soundness, gasket fit and epoxy coating before packing, and spare gaskets travel with bulk supplies so crews can re-seat the seal during later inspection. The ductile iron body is examined for cracks or porosity that would fail under bolt tension on a live main, and the blue epoxy coat is checked for missed patches in soil-contact areas. The elastomer gasket is fitted to the inside profile and checked for full length before dispatch, and housing bolts match the clamp size so crews have the complete repair set on site. Casting rigidity under bolt load is the property that lets the two halves or full wrap seal without removing a section of main.

Repair clamp entries listed

ReferenceMeasure
Model referenceDN50-DN1000
Product formRepair Clamp
End connectionSplit two-piece / full wrap
Standard reference-
Body materialDuctile Iron
Typical serviceTap water, sewage and industrial water
Size rangeDN65 to DN1200
Listed categoryDuctile Iron Pipe
Pressure ratingPn10 / Pn16 (up to PN25)
Ductile iron split two-piece repair clamp wrapped around a leaking water main
Ductile iron repair clamp, split two-piece or full wrap, DN65 to DN1200 for live mains.

Emergency stops on live water, sewage and industrial lines

A utility calls after a burst. They state the pipe OD, and the clamp seals it without digging the whole main out.

Municipal tap water networks develop leaks at joints, corrosion pits and small splits along buried mains, and repair crews carry these clamps to stop weeping before the excavation crew can open the trench. Sewage collector lines around districts and industrial yards use the same clamp on live branches where shutdown would disrupt service, and industrial water mains in plants and processing sites get emergency seals on cooling and transfer circuits. Bulk quantities supply utility crews that respond to burst calls year-round, and local depots hold stock for same-day dispatch. Clamps go on buried mains, surface exposed runs and ductile or steel barrels whose outside diameter falls in the listed size band.

Clamp sizing after a burst

Clamp size follows the pipe outside diameter measured at the repair point, and pressure rating matches the working pressure recorded on the main. Split two-piece suits short local leaks, while full wrap covers longer damaged zones where the split or corrosion area extends along the barrel. Opening orders start at the listed bulk quantity, and the per-piece bracket plus delivery window are agreed when the order enters the plant record. Each clamp is inspected for casting soundness, gasket fit and epoxy coating before packing, and spare gaskets travel with bulk supplies so crews can re-seat the seal during later inspection.

Size follows the OD. Rating matches the main. Spare gaskets travel along.

Split and wrap repair bodies

Bulk quantities supply utility crews that respond to burst calls year-round, and local depots hold stock for same-day dispatch. Clamps go on buried mains, surface exposed runs and ductile or steel barrels whose outside diameter falls in the listed size band. Sewage collector lines around districts and industrial yards use the same clamp on live branches where shutdown would disrupt service, and industrial water mains in plants and processing sites get emergency seals on cooling and transfer circuits. Tap water networks also draw the body at joints, corrosion pits and small splits along buried mains where a fast stop keeps supply flowing before a planned replacement.

Clamp size is measured against the pipe outside diameter at the repair point, and the pressure rating matches the working pressure recorded on that main, because an undersized clamp will not seal a live burst and an overrated one still depends on gasket compression to hold the joint. Bulk supplies ship with spare gasket material, so a crew can re-seat the seal during later inspection without waiting for a new clamp set to arrive.

When a utility calls after a burst, the crew measures the pipe OD and sends out the clamp that seals the live main without digging the whole line up, and the split or wrap body compresses its gasket against the exterior until the weep stops. The main stays live.

Hot Tags: Ductile Iron Pipe Repair Clamp DN65, China Ductile Iron Pipe Repair Clamp DN65 manufacturers, carbon steel adapter fittings, carbon steel industrial piping components, carbon steel pipe joint fittings, carbon steel threaded connector fittings, pipe fitting kit, Seamless Carbon Steel Elbow